Contactor model |
LCI |
D09 |
DT20 |
D12 |
DT25 |
D18 |
DT32 |
D25 |
DT40 |
D32 |
operating current (le) |
InAC-3,θ≤60℃ |
A |
9 |
|
12 |
|
18 |
|
25 |
|
32 |
(Ue ≤ 440 V) |
InAC-1,θ≤60℃ |
A |
25 |
20 |
25 |
25 |
32 |
32 |
40 |
40 |
50 |
Rated operating voltage (Ue) |
upper limit |
V |
690 |
|
690 |
|
690 |
|
690 |
|
690 |
Frequency range |
Under operating current |
Hz |
25...400 |
|
25...400 |
|
25...400 |
|
25...400 |
|
25...400 |
Agreed upper limit of heating current |
0“60℃ |
A |
25 |
20 |
25 |
25 |
32 |
32 |
40 |
40 |
50 |
Rated connection capacity (440V) |
Complies with IEC947 standard |
|
250 |
250 |
300 |
450 |
550 |
Rated breaking capacity (440V) |
Complies with IEC947 standard |
|
250 |
250 |
300 |
450 |
550 |
Contactor model |
LCI |
D38 |
D40A |
D50A |
D65A |
D80 |
D95 |
D115(1) |
D150(1) |
D170 |
operating current (le) |
InAC-3,θ≤60℃ |
A |
38 |
40 |
50 |
65 |
80 |
95 |
115 |
150 |
170 |
(Ue ≤ 440 V) |
InAC-1,θ≤60℃ |
A |
50 |
60 |
80 |
80 |
125 |
125 |
200 |
200 |
200 |
Rated operating voltage (Ue) |
upper limit |
V |
690 |
690 |
690 |
690 |
690 |
690 |
1000 |
1000 |
1000 |
Frequency range |
Under operating current |
Hz |
25...400 |
25...400 |
25...400 |
25...400 |
25...400 |
25...400 |
25...400 |
25...400 |
25...400 |
Agreed upper limit of heating current |
0“60℃ |
A |
50 |
60 |
80 |
80 |
125 |
125 |
200 |
200 |
200 |
Rated connection capacity (440V) |
Complies with IEC947 standard |
|
550 |
800 |
900 |
1000 |
1100 |
1100 |
1260 |
1660 |
1660 |
Rated breaking capacity (440V) |
Complies with IEC947 standard |
|
550 |
800 |
900 |
1000 |
1100 |
1100 |
1100 |
1400 |
1400 |