Brand | Model | Applicable |
STEP | SM.08/G | STEP elevator |
STEP universal debugger SM.08/G decond generation derver AS380 handheld operator.
·Functional characteristicstics
Elevator parameter setting: Through the handheld operator, you can set relevant parameters, such as: the number of elevator floors, elevator speed, etc.
Elevator status monitoring can display the following elevator status information:
Elevator operation status, such as automatic, maintenance, driver, fire, etc.;
The floor position and running direction of the elevator;
The elevator operation record and error code;
The elevator shaft data;
The elevator input and output status;
·Elevator shaft self-learning: Through the handheld operator, during the elevator debugging process, the shaft learning operation is performed to let the control system learn the reference position of each floor of the elevator and record it for filing.
Monitoring and registration of elevator calls and instructions: Through the handheld operator, you can monitor whether there are calls and instructions on each floor. You can also register the instructions or call signals of any floor through it.
·Fault code query: Through the handheld operator, you can check the elevator fault codes of the last 20 times and the floor position and time of the elevator when each fault occurs.
Supports the debugging of multiple products such as motherboards, all-in-one machines, and inverters
Operation indicator light:
D1: Safety circuit indicator light
D2: Door lock circuit indicator light
D3: Upward direction indicator light
D4: Downward direction indicator light