Brand | Type | Power | INPUT | OUTPUT | Applicable |
Thyssen | BG101-S20P2S/BG101-S20P4A | 0.2KW | 1PH AC 180-264V 50/60Hz | 0-INPUT 0-50Hz 1.0A | Thyssen elevator |
Debug:
1. Ensure that the landing door/car door is not linked and the door opens and closes smoothly. Pull the car door to the half-open state. Unplug the signal plug-ins P2 and P5. After confirming that the power supply is single-phase AC 180~264V, power on;
2. Carry out door machine self-learning by pressing and holding the left button for 3 seconds. At this time, the mode light turns on and the mode light goes out. The learning is completed. Plug in the signal broadcasts P2 and PS.
Notice:
1. Set P01.14=21 to restore factory values;
2. When the door machine is learning, first close the door, then open the door and then close the door. Otherwise, change the door machine running direction through P01.04.