Parameter | Function Description |
A1 | 00-Terminal control; 01-Panel jog; 02-Panel manual; 03-Automatic door opening and closing (for demonstration) |
A3 | 00/01 encoder phase sequence selection (if the door opening pulse display value decreases and the closing value increases, it needs to be modified) |
A4 | 00/01 Motor phase sequence selection (if the door opening and closing direction is opposite to the requirement, it needs to be modified) |
A7 | 00-07 Door machine type selection (the door runs too slow or too fast under the default parameters, you need to confirm whether the A7 parameters are correct) 00-Direct transmission 02-Reserved 07-Heavy-loaded high-speed ladder Others-With reduction ratio transmission (01-1 type Door operator 2500 to 3000nm; 03-1500 to 2500mm; 04-less than 1500mm; 06-2 door operator 2500 to 3000mm) |
Group E | Speed adjustment: E1 = base frequency (Hz); E2-E6 are % of the base; E7 is % of the base. |
Group C | Acceleration and deceleration adjustment: C1=base time (seconds); C2-C7 are % of base; E7=emergency stop time (light curtain protection). |
Group U | Torque adjustment: 220V = base voltage; U1-U4 are % of the base (see the "voltage-frequency ratio curve" in the instruction manual for details) |
Group H | Multi-function input (01-05 is valid when closed; 06-10 is valid when open) 00-not used 01/06 close door input 02/07-open door input 03/08-slow door close input 04/09-electric follow signal |
Group P | Multi-function output (01-04 is valid when closed; 05-08 is valid when open) 00-not used 01/05-close the door in place 02/06-open the door in place 03/07-door obstacle 04/08-system failure 09/10-close the door Output in advance |
Group L | L1=01-take out the factory default values (the system parameters remain unchanged, please refer to the manual for details); L2=01-door machine self-learning |
*A3 A4 A7 are hidden parameters. Set A1=03; A6=33 to display and allow modification.